750KVA Oil Immersed Distribution Transformer 3ph 440V Oil Type Distribution Transformer

750KVA Oil Immersed Distribution Transformer 3ph 440V Oil Type Distribution Transformer

MOQ: 1unit
Price: $500~$60000/Unit
Standard Packaging: 1000set/month
Delivery Period: 15~30days
Payment Method: T/T
Supply Capacity: Plywood case
Detail Information
Place of Origin
CHINA
Brand Name
Leilang Electric
Certification
CE,ISO
Model Number
S11-500
Type:
Oil Type
Primary Voltage:
0.1kv-36kv
Secondary Voltage:
220V, 440V
Standard:
IEC60076/GB1094
Frequency:
50/60Hz
Material:
Copper / Aluminium
Cooling Method::
ONAN/KNAN
Connection Symbol::
Dyn11/Yyn0
Highlight:

750kva oil immersed distribution transformer

,

oil immersed distribution transformer 3ph

Product Description
750KVA 3-Phase Oil-Immersed Transformer 10kV to 440V | S11 Low Loss, Anti-Short Circuit Design
Product Overview

Leilang Electric, an ISO 9001 certified global manufacturer of industrial power distribution equipment with 15+ years of specialized transformer engineering experience, presents our S11-750KVA 3-phase outdoor oil-immersed distribution transformer. This high-performance unit delivers reliable power conversion from 10kV primary to 440V secondary voltage, supporting both 50Hz and 60Hz frequency systems for industrial, mining, and petrochemical applications worldwide.

Core Verified Advantages
  • S11 Ultra-Low Loss Technology: Built with high-grade cold-rolled silicon steel cores to minimize energy waste, achieving industry-leading no-load and on-load loss performance that reduces operational costs by up to 35% over older transformer generations.
  • Enhanced Anti-Short Circuit Design: Features a new insulating structure, multi-layer cylindrical high-voltage windings, and specially treated anti-loose fasteners to withstand extreme electrical stresses and ensure long-term system stability.
  • Dual International Standard Compliance: Manufactured in strict accordance with IEC 60076 and GB 1094 standards, with additional CE and ISO certifications, guaranteeing global safety and performance compatibility.
Flexible Configuration Options

We offer both 100% oxygen-free copper and high-grade aluminum winding options to meet your budget and performance requirements. The transformer supports standard connection symbols Dyn11/Yyn0 and cooling methods ONAN/KNAN, with customizable voltage ratings from 0.1kV to 36kV for specialized project needs.

Detailed Technical Specifications
Model Number S11-750KVA
Rated Capacity 750 kVA
Phase 3 Phase
Primary Voltage 10kV (0.1kV-36kV customizable)
Secondary Voltage 440V (220V customizable)
Tap Range ±5% or +2×2.5%
Connection Symbol Dyn11 / Yyn0
Frequency 50/60 Hz
Cooling Method ONAN / KNAN
Winding Material 100% Oxygen-Free Copper / Aluminum (optional)
No-Load Loss 980 W
On-Load Loss 8750 W
No-Load Current 0.7%
Short-Circuit Impedance 6.5%
Insulation Class Class A
Temperature Rise 65°C
Ambient Temperature -25°C to +40°C
Standards Compliance IEC 60076, GB 1094, CE, ISO 9001
Additional Capacity Options (S11 Series)
 
odel Rated Capacity
(kVA)
Connection Symbol Hight Voltage
(v)
Tap range Low Voltage
(v)
No-load Loss On-load Loss No-load current Short-circuit impedance
(W) (W) (%) (%)
S11-50/35 50 Yyn0
or
Dyn11
35 ±5%
+2×2.5%
0.4 160 1200 1.3 6.5
S11-100/35 100 230 2010 1.1
S11-125/35 125 270 2370 1.1
S11-200/35 200 340 3320 1
S11-250/35 250 400 3960 0.95
S11-500/35 500 680 6910 0.85
S11-630/35 630 830 7860 0.65
S11-1000/35 1000 1150 11500 0.65
S11-1250/35 1250 1400 13900 0.6
S11-2000/35 2000 1990 19700 0.55
S11-2500/35 2500 2360 23200 0.55
Core Engineering Advantages
  1. Industry-Leading Energy Efficiency: The S11 series uses high-quality cold-rolled silicon steel cores with precision lamination to reduce core losses, delivering significant energy savings over the transformer's 30+ year service life.
  2. Superior Short-Circuit Resistance: Our proprietary insulating structure and multi-layer cylindrical winding design provide exceptional mechanical strength, while all fasteners undergo special anti-loose treatment to prevent damage during fault conditions.
  3. Premium Material Construction: Selected oxygen-free copper wire ensures high conductivity and thermal stability, while the robust steel enclosure provides excellent protection against harsh outdoor environments.
  4. Low Noise & Low Partial Discharge: Advanced manufacturing processes result in quiet operation (<60 dBA) and minimal partial discharge, making this transformer suitable for noise-sensitive industrial and commercial areas.
  5. Easy Installation & Maintenance: Compact and lightweight design reduces transportation and installation costs, while the sealed oil system minimizes maintenance requirements for long-term reliability.
Quality Assurance & Support

All Leilang Electric transformers undergo a rigorous 12-step quality control process certified to ISO 9001 standards:

  • Raw material inspection and material certification verification
  • Winding resistance and insulation resistance testing
  • Core loss and excitation current measurement
  • Short-circuit impedance and voltage ratio testing
  • High-voltage withstand and partial discharge testing
  • Final comprehensive performance verification and oil quality analysis

We support sample orders for quality verification and offer full OEM/ODM customization services, including custom voltage ratings, tap ranges, enclosure colors, and branding. With a monthly production capacity of 1,000 units and a standard lead time of 15-25 days, we can meet both small-scale and large project requirements. All products come with a 24-month warranty from the bill of lading date and lifetime technical support from our team of certified electrical engineers.

750KVA Oil Immersed Distribution Transformer 3ph 440V  Oil Type Distribution Transformer 0 750KVA Oil Immersed Distribution Transformer 3ph 440V  Oil Type Distribution Transformer 1
Frequently Asked Questions
Q: What international standards does Leilang Electric's 750KVA oil-immersed transformer comply with?
A: Our S11-750KVA transformer is manufactured in strict accordance with IEC 60076 international standards and Chinese GB 1094 standards. It also holds CE and ISO 9001 certifications, ensuring compliance with global safety and performance requirements.
Q: Can I choose between copper and aluminum windings for this transformer?
A: Yes, we offer both 100% oxygen-free copper windings (for maximum performance and longevity) and high-grade aluminum windings (for cost-sensitive applications). Our engineering team can help you select the best option for your specific project.
Q: How much energy will the S11 low-loss design save compared to older transformers?
A: The S11 series reduces no-load losses by approximately 35% compared to traditional S9 series transformers. For a 750KVA transformer operating 24/7, this translates to over 2,600 kWh of annual energy savings, significantly lowering your electricity bills and carbon footprint.
Q: What makes this transformer resistant to short-circuit damage?
A: It features an advanced new insulating structure, multi-layer cylindrical high-voltage windings, and specially treated anti-loose fasteners. These design elements provide exceptional mechanical strength to withstand the high forces generated during short-circuit events.
Q: What customization options are available for this 750KVA transformer?
A: We provide comprehensive OEM/ODM services, including custom voltage ratings (0.1kV-36kV), tap ranges, connection symbols, cooling methods, enclosure colors, and branding. All custom designs are reviewed and approved by our certified engineering team before production.
Q: What quality control measures do you implement to ensure product reliability?
A: Each transformer undergoes 12+ quality checks throughout production, from raw material inspection to final performance testing. We test winding resistance, insulation resistance, core losses, impedance, and high-voltage withstand capability. All products are shipped with a detailed test report.